logo
المنزل > المنتجات > جهاز استشعار جودة المياه >
PPM DO Dissolved Oxygen Probe Transmitter Sensor Fast Response High Accuracy

PPM DO Dissolved Oxygen Probe Transmitter Sensor Fast Response High Accuracy

water turbidity sensor,oil in water sensor

oil in water sensor

Place of Origin:

China (Mainland)

اسم العلامة التجارية:

Kacise

إصدار الشهادات:

certificate of explosion-proof, CE

Model Number:

KBU601

اتصل بنا
اطلب اقتباس
تفاصيل المنتج
Product name:
Aquaculture Fluorescence Dissolved Oxygen Sensor
Range:
0-20mg/L or 0-200% saturation
Accuracy:
±5%
IP Grade:
IP68
Sensor Drift:
<1% per year
Output:
RS485
إبراز:

water turbidity sensor,oil in water sensor

,

oil in water sensor

شروط الدفع والشحن
Minimum Order Quantity
0-100
الأسعار
USD200-USD600
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 working days
Payment Terms
Western Union, MoneyGram, T/T
Supply Ability
100
وصف المنتج

Optical Fluorescence Waste Sea Water Fish Farm Agriculture PPM DO Dissolved Oxygen Probe Transmitter Sensor

 

Introduction
 
The Kacise KWS-600 fluorescence dissolved oxygen sensor is designed for the aquaculture industry. It has the characteristics of stable online monitoring, and it has excellent characteristics compared with the traditional type sensor. It has no membrane, no need electrolyte, strong anti-interference, no need for frequent calibration, no consumption of oxygen, no flow rate limitation, auto matic temperature and Gas pressure compensation, gast reaction speed, long service life and more economical and convenient, so the fluorescence dissolved oxygen sensor is the best choice for real-time dynamic monitoring of oxygen content in aquaculture.
 
Features
  • No membrane, no need electrolyte
  • No need to consume oxygen, not affected by flow rate
  • Built-in temperature sensor, automatic temperature compensation
  • Free from chemical interferences such as sulfides
  • Small annual drift, fast response, and more accurate measurement
  • Free of maintenance, longer application cycle and lower cost of use
  • Fluor cap replacement is simple
  • Support RS-485, MODBUS protocol

 

Technical Specifications
 
Range 0-20mg/L or 0-200% saturation
Accuracy ±5%
Response Time 3 min
Ip Grade IP68
Sensor Drift <1% per year
Operating Temperature 0~50℃
Temperature Accuracy Temperature Accuracy
Output RS485, Modbus
Power Supply DC6-12V ±5%, current<50mA
Temperature Sensor NTC
Casing Diameter 22mm
Casing Length 188.3mm
Cable Length Standard 10m, customizable 5m, 15m and 30m
Fluorescent Cap Lifetime 1 year (under normal use)
Casing Material POM
 
 

PPM DO Dissolved Oxygen Probe Transmitter Sensor Fast Response High Accuracy 0

 

 PPM DO Dissolved Oxygen Probe Transmitter Sensor Fast Response High Accuracy 1

 

PPM DO Dissolved Oxygen Probe Transmitter Sensor Fast Response High Accuracy 2

 

 


 

 

أرسل استفسارك مباشرة إلينا

سياسة الخصوصية الصين جودة جيدة مقياس مستوى السوائل المورد. حقوق الطبع والنشر © 2018-2025 Xi'an Kacise Optronics Co.,Ltd. جميع الحقوق محفوظة